Solar Controller CLTD(12-24)-10A
Technical Information:
|
LED
Status |
Control Status |
Battery Status |
Control Voltage |
|
RED
LED |
GREEN
LED |
RED
LED |
GREEN
LED |
RED
LED |
GREEN
LED |
|
Bright |
Over-Circuit Protection |
Solar Power Indication |
Low Volt. Alarm |
Normal Voltage |
24V Battery |
12V Battery |
|
Flash |
Over-Temp. Protection |
|
Discharge Proction |
Charge Protection |
|
|
(1) Indication:
The controller automatically selects for12V and 24V system.
|
Main functions |
12V system |
24V system |
|
High voltage charge disconnect(HVCD) |
14.4V |
28.8V |
|
Low voltage load disconnect (LVD) |
10.9V |
21.8V |
|
LVD reconnect |
12.2V |
24.4V |
|
Low voltage alarm |
11.8V |
23.6V |
|
Load over-current protection |
5A 10A |
|
Temperature compensation |
-4mV/℃/cell |
|
Operating temperature |
-40℃ ~ 85℃ |
|
Over temperature protection |
Both panel and load are disconnected, if temperature exceed the range of -35℃ ~ 80℃ |
|
Light Control |
Turn the light on at night and off in morning |
|
Timing Control |
Selection by connecters |
(2) Control function setup by choosing the connecters.
TIMEA set LOADA status
TIMEB set LOADB status
Select the connecter (1,2,3,4,5,6,7,8) in the side of controller, Timing status indicate
|
Connecter |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
|
TIMEA
(Hours) |
Charge & Load control |
Light control |
3 |
4 |
5 |
6 |
7 |
8 |
|
TIMEB
(Hours) |
Charge & Load control |
Light control |
5 |
6 |
7 |
8 |
9 |
10 |
Attention: Both two buttons must be selected; if one select No.1, the others must use No.1.
|